Meaning
Measurement scale quantifying the resistance of solid insulating materials to tracking under electric stress and humidity. The comparative tracking index provides a relative measure of how easily a surface conducts electricity when contaminated with electrolyte or water. High values indicate better performance in high voltage battery enclosures where condensation occurs.
Insulation Quality
Property ratings for plastics used in battery modules often specify a minimum value to prevent fire risk. Selecting a material with a high comparative tracking index helps the housing withstand internal creepage currents even if moisture enters the pack.
Measurement Procedure
Testing involves applying 50 drops of a standardized electrolyte solution to the surface of the specimen while two electrodes maintain a fixed voltage. This process repeats across several samples to find the maximum voltage at which no failure occurs after the full droplet count. Analysts look for the formation of conductive carbon tracks that bridge the gap between metal points.
A failure occurs if the current exceeds 0.5 amperes for a duration of two seconds.
Design Standard
Compliance with safety certifications like UL 746A or IEC 60112 requires documented evidence of these performance levels. Mechanical engineers use the comparative tracking index to determine the minimum spacing required between high voltage busbars and grounded metal parts.