Meaning
Formation of a permanent conductive path across the surface of an insulating material due to the carbonization of the polymer.
Degradation Mechanism
Electrical stress breaks down the chemical bonds of the insulator and creates a trail of carbon. As surface tracking progresses, the resistance of this path drops and allows more current to flow, which generates heat and further damages the material. This self reinforcing cycle eventually leads to a catastrophic short circuit or a fire within the electrical system.
The rate of this degradation depends on the voltage gradient and the tracking resistance of the specific plastic used.
Design Mitigation
Engineers specify materials with a high comparative tracking index to prevent these failures in high voltage battery packs. Increasing the creepage distance between terminals is another common method to reduce the likelihood of surface tracking. By designing housings with physical barriers or ribs, the path for potential leakage current becomes much longer and more difficult to sustain.
Environmental Factor
Humidity and pollution markedly lower the voltage at which this process begins. Regular maintenance and sealed enclosures help to keep the insulating surfaces clean and dry. Keeping the environment controlled is the best way to prevent unexpected electrical paths.