Meaning
Computed tomography scans of battery internals depend on the size of the smallest three-dimensional pixel in the reconstructed image. This voxel resolution determines the level of detail visible in the stack, from the placement of tabs to the presence of metallic particles. A smaller voxel allows for the inspection of features that are invisible to standard X-ray systems.
Scanning Parameter
Physical limitations of the X-ray source and the detector distance set the minimum achievable value for this metric. When the voxel resolution is high, the system can distinguish between different layers of the electrode and the separator. Reaching a resolution of a few microns requires a stable stage and a high-flux source.
These settings are calibrated before every scan to ensure the dimensional accuracy of the results.
Defect Identification
Quality assurance teams use these scans to look for electrode misalignment or delamination inside sealed prismatic cells. A sufficient voxel resolution makes it possible to see if the anode overlaps the cathode correctly at every edge. It also allows for the detection of small voids in the electrode coating that might lead to lithium plating.
This non-destructive inspection is necessary for analyzing cells that failed during safety testing.
Analytical Tradeoff
Increasing the detail in a scan greatly increases the amount of time required for data acquisition and processing. Very fine voxel resolution generates massive data sets. These sets require specialized hardware to visualize.
Manufacturers must choose a setting that provides enough detail to find critical flaws without slowing down the production line excessively. Balancing this speed and detail is the primary challenge in implementing automated CT inspection for high-volume cell manufacturing.