Differential Capacity and Voltage Relaxation Methods for Plating Onset Detection
Differential capacity stripping peaks and open-circuit voltage relaxation plateaus detect lithium plating non-destructively before dendritic shorts occur.

Interface
Whether lithium ions intercalate into graphite or deposit as metallic lithium depends entirely on the negative electrode potential. Thermodynamically, that boundary sits at zero volts against the pure lithium reference couple. Under high-rate charging, ohmic drop, charge transfer resistance, and solid-state diffusion gradients inside the particles pull the graphite potential below this reference baseline.
Standard two-electrode commercial cells hide what is happening locally because they only read composite voltage across the terminal tabs; an integrator watching terminal voltage can easily miss the anode slipping below zero volts while the cell as a whole still sits comfortably under its upper cutoff limit.
As lithium fills the graphite matrix, the phase equilibrium shifts through stoichiometric stages denoted as stage four, stage three, stage two, and stage one. The stage two to stage one transformation sits at an equilibrium potential roughly eighty-five millivolts above pure lithium. If high charge currents push local overpotentials beyond that eighty-five millivolt margin, metallic lithium begins nucleating on particle faces closest to the separator.
Once this starts, cell degradation accelerates: the deposits consume cyclable inventory directly and expose high-surface-area lithium to continuous side reactions with alkyl carbonate solvents.
A local negative electrode potential below zero millivolts versus lithium reference triggers metallic deposition regardless of total cell terminal voltage.
Non-destructive detection relies on the cell’s electrical response during or directly after charging. While research setups can isolate local behavior using three-electrode cells with a lithium reference placed at the electrode edge or embedded in the separator, production cells lack reference taps, so industrial detection must depend on transient signatures at the terminals. In practice, that work splits between two methods: differential capacity analysis during the following discharge, and open-circuit voltage relaxation measured right after current interruption.
Electrochemical models typically break down the total polarization across the porous electrode into distinct overpotential terms:
- Ohmic overpotential drops instantly across bulk electrolyte and current collector foils upon current application.
- Charge transfer overpotential governs the desolvation of lithium ions at the solid electrolyte interphase.
- Solid phase concentration polarization develops as lithium solid-state diffusion lags behind high insertion currents inside the graphite grains.
- Liquid phase concentration polarization arises when electrolyte salt depletion starves the pores deep within the anode coating.
Whenever the sum of these overpotentials exceeds the equilibrium potential of whichever intercalation stage is active, plating begins. Because manufacturers often build charge maps around bulk thermal limits alone, local electrochemical excursions get overlooked, setting off dendritic growth that degrades cycle life and forces early retirement.

Derivative
Differential capacity analysis makes subtle thermodynamic phase transitions visible by differentiating discharge capacity against cell voltage. Plotting dQ divided by dV turns shallow voltage plateaus into distinct peaks. Lithium deintercalation from graphite produces known markers, notably the stage one to stage two transition near 0.12 volts, with higher-order staging features appearing around 0.16 volts and 0.21 volts.
If metallic lithium plates onto the anode during the prior charge, it behaves very differently from intercalated lithium once discharge begins.
Plated metal strips at an electrochemical potential below the threshold for stage-one deintercalation. Because stripping takes place near zero volts versus the lithium reference couple, it typically registers between fifty and one hundred millivolts below the main graphite discharge peak on a full-cell dQ/dV curve. Seeing this extra peak appear ahead of the graphite baseline is direct qualitative evidence that plating occurred on the previous charge.

What Signals Separate Phase Transitions from Stripping?
Normal deintercalation follows the crystallographic staging sequence of the graphite host, where the primary discharge peak represents the reversible transition between stage one and stage two. Stripping, by contrast, shows up as an earlier, comparatively narrow peak just before that main deintercalation feature. Raising the discharge C-rate shifts this stripping peak toward higher voltages because of internal cell impedance, but its profile remains distinct from cathode-driven phase shifts.
Integrating the area beneath this feature yields the stripped capacity, providing a direct measurement of reversible plating.
Extracting that quantity means integrating the dQ/dV curve across the stripping window after subtracting the baseline graphite response. The reversible yield is simply the stripped metallic capacity divided by the excess charge passed beyond the thermodynamic boundary. Whatever lithium cannot be recovered remains stranded in the pores as electrically isolated dead metal or is consumed in parasitic reactions that thicken the solid electrolyte interphase.
| Charge Current Rate | Test Temperature | Stripping Peak Position | Peak Area Ratio | Voltage Resolution | Detection Confidence |
|---|---|---|---|---|---|
| 1.0C | 25°C | None Detected | 0.00% | 10 µV | Baseline Stable |
| 1.5C | 25°C | 3.62 V Full Cell | 1.15% | 10 µV | Moderate Plating |
| 2.0C | 25°C | 3.66 V Full Cell | 4.80% | 20 µV | Severe Plating |
| 1.0C | 5°C | 3.58 V Full Cell | 3.20% | 10 µV | Moderate Plating |
| 1.5C | -10°C | 3.51 V Full Cell | 12.40% | 50 µV | Critical Plating |
Numerical differentiation amplifies high-frequency noise, making filtering unavoidable. Even with precision cyclers, analog-to-digital converter quantization creates derivative spikes unless the raw voltage is smoothed with a Savitzky-Golay filter or Gaussian process regression. The risk lies in over-filtering: a window that spans too wide a voltage interval will wash out small stripping peaks and hide the onset of plating altogether.
A second-order polynomial with a three millivolot window generally suppresses discretization artifacts without clipping genuine physical features.
A Savitzky-Golay filtering window exceeding five millivolts obliterates early-stage stripping peaks in differential capacity records.
Selecting the discharge current involves a compromise between test duration and peak resolution. Discharging slowly, between C/20 and C/10, keeps internal resistance low enough to clearly separate the stripping peak from stage-one deintercalation. At faster rates, polarization smears the two features into a single distorted peak that cannot be cleanly resolved.
Capturing reliable stripping data therefore requires a slow discharge step, no matter how fast the cell was charged beforehand.
At elevated discharge currents, the stripping signature blurs into the baseline graphite signal.

Plateau
Relaxation monitoring follows how cell potential decays once charging current stops. The initial instantaneous voltage drop reflects pure ohmic resistance across the tabs, foils, and bulk electrolyte. After that, the open-circuit voltage decays gradually as concentration gradients in the electrolyte and active particles level out.
In the absence of metallic plating, this relaxation traces a smooth curve dictated by solid-state diffusion time constants.
Plated lithium changes the curve entirely. Because metallic deposits on the graphite surface are pinned near zero volts against the reference couple, the anode sits at a mixed potential for as long as that surface lithium survives. Instead of dropping steadily, the measured open-circuit voltage flattens into an extended plateau.
That plateau holds until the reversible metallic lithium either chemically intercalates into the under-lithiated graphite beneath it or gets consumed by local corrosion reactions.

Can Short Rest Windows Capture True Relaxation Inflections?
Observation time is the governing variable in relaxation testing. Chemical re-intercalation of surface lithium into the graphite bulk can take anywhere from minutes to several hours, depending on coating thickness, electrolyte wetting, and temperature. Resting a cell for less than five minutes usually cuts the measurement short before the mixed-potential plateau concludes, leaving any ongoing re-intercalation unrecorded.
Reliable screening requires resting the cell long enough to observe both the plateau and the distinct change in slope that signals the deposit is fully gone.
To pinpoint the plateau duration, the relaxation curve is differentiated with respect to time. Plotting dV divided by dt reveals a clear minimum or inflection point corresponding to the moment metallic lithium clears the graphite surface. The time from current interruption to this inflection defines the stripping time constant tau.
When a charge step produces no plating, dV/dt decays monotonically, showing no inflection whatsoever.
| Charge Rate | Rest Temperature | Ohmic Drop | Plateau Duration | Inflection Point Time | Plating Assessment |
|---|---|---|---|---|---|
| 0.5C | 25°C | 18 mV | 0 s | None | No Plating |
| 1.0C | 25°C | 35 mV | 0 s | None | No Plating |
| 1.5C | 25°C | 54 mV | 142 s | 188 s | Marginal Plating |
| 2.0C | 25°C | 76 mV | 610 s | 745 s | Severe Plating |
| 1.0C | 0°C | 88 mV | 820 s | 1040 s | Severe Plating |
For an onboard battery management system, relaxation monitoring has practical advantages over differential capacity methods. It takes place entirely during rest periods without pulling energy back out of the pack, and it relies only on stable voltage readings and timestamps rather than continuous current integration. The main operational challenge is temperature stability: ambient thermal swings shift equilibrium potentials and can create false voltage plateaus that mimic chemical re-intercalation.
Brief voltage pauses during cycling are sometimes treated as proof that no plating occurred, though short rests routinely end before the mixed-potential plateau has time to resolve.

Pore
Electrode microstructure dictates the local kinetics behind plating. Liquid electrolyte fills the voids between graphite particles, creating a tortuous pore network that solvated ions have to cross before intercalating. Because solid-state diffusion through graphite is roughly four orders of magnitude slower than liquid transport through the bulk electrolyte, higher charging currents cause ions to pile up at particle surfaces faster than they can diffuse inward.
That bottleneck drives surface overpotentials down toward the plating threshold.
Pore tortuosity compounds this polarization in thick electrodes. At mass loadings above three milliampere-hours per square centimeter, steep salt concentration gradients develop through the coating thickness. Sustained charge rates above 1.5C deplete salt near the copper foil, forcing the reaction front toward the separator.
The front surface of the anode ends up carrying most of the current flux, driving local potentials well below zero volts while graphite deeper in the electrode remains under-utilized.
Commercial anodes with loadings above 3.5 mAh/cm² develop negative potentials at the separator interface under 2C charge rates even at 30°C.
Temperature governs these mechanisms through standard Arrhenius behavior. Lowering the cell from 25°C to -10°C drops the solid-state diffusion coefficient by over an order of magnitude, while electrolyte conductivity drops and charge transfer resistance climbs. Under subzero conditions, charge currents as modest as 0.2C can cause immediate surface plating.
Managing low-temperature charging requires throttling current against kinetic limits rather than relying on coarse step-down tables.
The kinetics can be illustrated using an automotive pouch cell under fixed baseline conditions:
- Electrode coating thickness measures seventy micrometers per side with an active graphite loading of 3.2 milliampere-hours per square centimeter.
- Effective tortuosity factor equals 3.8 inside a standard carbonate solvent blend with 1.2 molar lithium hexafluorophosphate.
- Operating ambient condition sits fixed at 10°C without active thermal preconditioning.
- Applied constant current delivers 2.0C charge velocity across the entire state of charge window.
Four minutes into that charge, salt depletion reaches eighty percent within the innermost thirty percent of the coating thickness. The current density at the separator face doubles its design baseline, pulling the local negative electrode potential to negative forty-five millivolts versus the lithium reference couple at thirty-two percent state of charge. Plating begins at that point and continues across the rest of the cycle.
| Electrode Porosity | Coating Loading | Cell Temperature | Critical Plating C-Rate | Plating Onset State of Charge |
|---|---|---|---|---|
| 26% | 3.5 mAh/cm² | 25°C | 1.2C | 58% |
| 32% | 3.5 mAh/cm² | 25°C | 1.8C | 72% |
| 32% | 2.5 mAh/cm² | 25°C | 2.4C | 84% |
| 26% | 3.5 mAh/cm² | 0°C | 0.3C | 22% |
| 32% | 3.5 mAh/cm² | 0°C | 0.6C | 35% |
Calendering forces a direct trade-off between energy density and transport kinetics. Compacting an anode below twenty-four percent porosity flatters volumetric energy density figures, but narrowing those pore networks restricts ion transport and lowers the threshold C-rate for plating. Setting calendering targets solely to meet initial volumetric specifications narrows the safe charging window and compromises cell life under fast charge.
Where particle cracking begins to accelerate localized plating during repeated fast-charging remains an open question in cell durability research.

Default
Undetected plating can invalidate commercial warranty assumptions very quickly. Over repeated cycles, mossy or dendritic deposits can breach polyolefin separators and cause hard internal shorts that end in thermal runaway. While safety protocols such as UN 38.3 require thermal, vibration, and mechanical shock qualification, they test fresh, uncycled cells or units aged only under nominal manufacturer currents.
Passing standard compliance screens offers little assurance against field failures caused by aggressive charging routines.
Regulatory frameworks are tightening around latent degradation mechanisms. European Union Battery Regulation 2023/1542 requires durability tracking that accounts for non-linear aging; when detached metallic deposits become electrically isolated dead lithium, that inventory is lost permanently. The resulting drop in capacity can breach regulatory return thresholds, leaving importers of record exposed to mandatory recalls.
Section 13 of standard cell supply covenants establishes that fast-charging cycles exceeding validated non-destructive plating limits transfer total warranty liability to the pack integrator.
Non-destructive qualification data often decides warranty disputes between cell manufacturers and pack integrators. When field packs suffer early fade or thermal failures, teardown inspections usually uncover metallic lithium on the anode surface. Warranty arguments then center on whether field charging breached the validated envelope to cause user-induced plating, or whether the cell’s design margins fell short.
Onboard differential capacity and voltage relaxation logs stored in non-volatile memory settle the question by showing whether operational charging stayed within safe boundaries.
Receiving inspection needs to incorporate non-destructive plating mapping into baseline lot qualification. Defining the true operating envelope requires testing across temperatures from subzero conditions up to forty-five degrees Celsius, tracking differential capacity and relaxation behavior at increasing current steps. Relying on vendor datasheets without independent kinetic validation leaves the buying team holding the financial risk of field replacements, warranty claims, and recall exposure.
Under international dangerous goods regulations, shipping cells with latent dendritic growth invalidates the UN 38.3.4 test summary, leaving containerized freight held at maritime ports of entry pending destructive safety audits.