Meaning
An electrochemical deterioration process degrades the aluminum channels, manifold interfaces, and brazed joints of liquid cold plates used in traction battery packs. Exposure to degraded glycol coolants or incompatible metal pairings drives cooling plate corrosion, which reduces thermal conductivity and introduces leakage paths into high-voltage environments. The degradation mechanism encompasses localized pitting, uniform surface oxidation, and galvanic coupling between dissimilar fittings.
Prevention requires strict coolant chemistry management, compatible braze alloys, and controlled fluid velocities.
Glycol Breakdown
Ethylene glycol and propylene glycol heat transfer fluids oxidize into acidic organic byproducts under elevated temperatures and prolonged aeration. Glycolic, formic, and oxalic acids form as thermal cycles accumulate, driving coolant pH downward from alkaline levels into acidic territory. Depleted corrosion inhibitor packages fail to replenish protective surface films on channel walls.
Acidic coolant strips the passive aluminum oxide layer, exposing bare metal to continuous dissolution. Corrosion rates multiply once fluid conductivity rises due to accumulated metal ions and dissolved breakdown products.
Channel Blockage
Insoluble corrosion products precipitate inside micro-channel cooling plates, restricting fluid passages and creating severe thermal imbalances across cell modules. Aluminum hydroxide flocculants and dislodged braze residues accumulate at header inlets and narrow channel turns. Flow stagnation in choked passages elevates local cell temperatures during high-rate discharge.
Uneven thermal distribution accelerates cell aging and reduces available battery pack power output. Complete channel obstruction starves isolated modules of cooling fluid, which triggers localized hot spots and module-level safety shutdowns.
Thickness Allowance
Mechanical engineers incorporate sacrificial wall thickness into extruded and stamped cooling plates to counteract long-term metal loss. Coolant plates fabricated from three-thousand series aluminum alloys feature core materials clad with four-thousand series brazing alloys, creating complex galvanic interfaces at every seam. Selecting compatible brazing filler metals minimizes localized galvanic attack along the braze fillet.
Quality assurance programs enforce baseline coolant purity standards, requiring low chloride and low sulfate concentrations in supply batches. Regular fluid sampling during endurance validation measures inhibitor depletion before wall perforation occurs.