Meaning
Standardized safety protocols established by the United Nations to evaluate the resilience of lithium-ion batteries against the hazards of transport govern the global distribution of cells. This T.1 to T.8 testing includes altitude simulation, thermal tests, vibration, shock, external short circuit, impact, overcharge and forced discharge. The testing applies to both individual cells and completed battery assemblies, ensuring they do not leak, vent, disassemble, rupture or catch fire.
Passing these tests is a legal prerequisite for shipping any lithium battery. No carrier will accept goods without a certified test summary.
Thermal Simulation
Transport environments expose batteries to extreme temperatures and pressures. During T.1 to T.8 testing, cells must withstand low pressure at high altitudes and rapid temperature transitions from hot to cold. These tests verify that the cell seals remain intact and do not leak electrolyte during transit.
Mechanical Abuse
Shock and vibration during road or air transport can cause internal short circuits. The mechanical tests within T.1 to T.8 testing simulate the physical stresses of shipping by subjecting cells to high-impact drops and continuous vibrations. This ensures that internal connections remain secure and free from physical damage.
Electrical Abuse
Abnormal electrical conditions such as overcharge can trigger thermal runaway. The electrical portion of T.1 to T.8 testing subjects the cells to currents and voltages far exceeding their rated limits. This proves that the internal safety vents and current interrupt devices function correctly under extreme stress.