Meaning
An international safety testing standard evaluates the ability of a lithium-ion cell or battery to withstand an external short circuit. This un 38.3 test t5 protocol requires the test sample to be subjected to a short circuit with a total external resistance of less than 0.1 ohm at a temperature of 55 degrees Celsius. It simulates a severe accidental short circuit that might occur during transport or handling.
Circuit Design
Low resistance connections are maintained for at least one hour after the battery temperature has stabilized. The test apparatus uses heavy-duty contactors to ensure the resistance does not rise during the high-current event. This setup forces the cell to discharge its energy as rapidly as possible, testing its internal safety features.
Thermal Stress
Internal cell temperatures can rise rapidly during the discharge, challenging the structural integrity of the separator. The test sample passes only if its casing temperature does not exceed 170 degrees Celsius and it does not explode or catch fire. This thermal limit ensures that any failure remains contained without catastrophic consequences, protecting the surrounding environment.
Compliance Documentation
Certification reports verify that the tested cells met all safety criteria before they are approved for commercial transport.