Test standards for particle size distribution establish sieve mesh fractioning protocols for granular metal powders. Standardized under ASTM B214 sieve testing, this method specifies mechanical shaking duration and screen dimensions to quantify particle retention across wire cloth sieves. The result yields a reproducible mass distribution curve across standardized mesh openings ranging from forty-five to eight hundred fifty micrometers.
The specification stops applying when particle sizes drop below forty-five micrometers or when cohesive electrostatic forces disrupt free flow through the sieve wire cloth.
Mechanical Procedure
Sieve stack preparation requires nesting calibrated woven wire screens in descending order of aperture size above a solid receiving pan. A representative dry powder sample flows into the top sieve, whereupon the assembled stack undergoes standardized mechanical agitation for a specified duration. Controlled vertical impact and orbital rotation force undersized particles through individual mesh openings until separation reaches steady state.
Sieve Calibration
Precision wire cloth dimensions determine the separation accuracy of individual fraction cuts. Optical inspection tools verify wire diameter and aperture uniformity to prevent dimensional drift from wear over repeated test cycles. Standardized reference powders confirm screen integrity before official sample analysis proceeds.
Operational Limit
Cohesive fine powders below forty-five micrometers agglomerate on the screen surface rather than passing through openings. Non-spherical morphologies or high surface friction further inhibit complete passage, requiring air jet sieving or laser diffraction methods instead. ASTM B214 sieve testing provides reliable benchmark sizing only for free-flowing metallic particles within established screen dimensions.