Meaning
Testing procedures for thin metal components utilize a diamond indenter to measure the resistance of a surface to localized deformation. Micro-vickers hardness is determined by applying a force of less than one kilogram and measuring the resulting diagonal length of the impression. This metric is essential for verifying the quality of copper and aluminum foils used as current collectors in lithium-ion cells, but the test is not suitable for thicker rigid plates where macroscopic methods are required.
Indentation Load
The load applied during the test must be small enough to avoid penetrating the entire thickness of the foil. Because battery foils are often less than twenty micrometers thick, the test requires precise optical equipment to resolve the small indentation.
Mechanical Strength
Hardness values correlate with the tensile strength and ductility of the metal, which influences the durability of the foil during high-speed winding and calendering. If the material is too soft, it may stretch or tear under the tension of the coating machine. Conversely, excessive hardness often indicates brittleness, which leads to cracks during the expansion and contraction of the battery during use.
Measurement Accuracy
Evaluation of the hardness across the width of a foil roll ensures consistency in the manufacturing process. Discrepancies in these measurements signal issues with the annealing or rolling steps at the metal mill.