Meaning
Timing differences between the acquisition of current and voltage data points can lead to noticeable errors in power and impedance calculations. This phenomenon, called sampling phase skew, occurs when a battery management system does not measure the current and voltage of a cell at the exact same moment. Even a microsecond of delay between these two readings can distort the relationship between them during rapid transients.
It is a primary consideration for high frequency monitoring and fast charging control.
Calculation Impact
Dynamic impedance measurements rely on the simultaneous capture of the excitation signal and the response. When sampling phase skew is present, the calculated resistance and reactance values will shift, leading to incorrect state of health diagnostics. This is problematic in systems using digital signal processing to filter noise.
Firmware engineers must implement synchronization protocols or mathematical corrections to align the data streams in the time domain.
Measurement Error
Power estimation accuracy is directly affected by the temporal alignment of the sensors. If the sampling phase skew is not addressed, the instantaneous power value will be either over reported or under reported depending on the direction of the current change. This affects the precision of the coulomb counting algorithm used for fuel gauging.
High end measurement systems use hardware triggers to ensure that all data converters fire at the same instant.
Synchronization Method
Hardware designers use clock distribution networks to minimize the jitter and delay between different measurement nodes. Minimizing sampling phase skew requires careful board layout and the use of high speed communication buses. In large scale battery packs, the delay across several meters of wiring must also be considered.
Synchronous clocks are required. The final system architecture is designed to keep the temporal offset below the threshold that would affect the control stability.