Meaning
Rate at which transverse sound waves propagate through a solid material. This shear wave velocity is approximately half the speed of longitudinal waves and is only sustainable in solids that possess shear strength. It is a critical parameter in ultrasonic weld inspection, where shear waves are used to detect planar flaws that are oriented perpendicular to the surface.
Refraction Calculation
Incident longitudinal waves are converted into transverse waves when they hit the material interface at an angle. The shear wave velocity must be known accurately to calculate the correct refraction angle according to Snell’s law. Inaccurate values lead to errors in the depth and lateral position of defects, which can result in the rejection of acceptable parts or the failure to identify dangerous cracks.
Modulus Relationship
Elastic properties of the material, specifically the shear modulus and density, determine the propagation speed. The shear wave velocity is sensitive to changes in the material state, such as heat treatment or cold working, which alter the internal lattice structure. Measuring this speed provides a non-destructive way to monitor the mechanical properties of a component during its manufacturing or service life.
Measurement Accuracy
Calibration on a reference block of identical material is the only way to ensure the speed used in the instrument software is correct. The shear wave velocity varies slightly with temperature, so measurements should be taken at the same thermal equilibrium as the test piece.