Meaning
Stress acting parallel to the boundary plane between two bonded layers can cause delamination and structural separation. In composite battery electrodes, this stress is termed transverse interfacial shear, and it develops due to unequal expansion of the active material and the metal current collector.
Mechanics of Failure
During lithiation, the coating swells significantly while the aluminum or copper foil remains rigid and non-expanding. This differential strain generates transverse interfacial shear at the contact zone, which can rupture the adhesive binder bonds. When these bonds fail, the active layer peels away from the collector foil, causing immediate loss of electrical contact.
This mechanical degradation results in a rise in internal resistance and a corresponding decrease in the rate capability of the cell.
Measurement Method
Peel testing and scratch tests determine the maximum force needed to separate the active material from the current collector. Quantifying the resistance to transverse interfacial shear provides a direct measure of binder effectiveness and slurry mixing quality. Higher adhesion values indicate that the electrode can withstand the cyclic stresses of long-term cycling.
Adhesion Improvement
Treating the surface of the metal foil with chemical etching or corona discharge increases the surface roughness and bonding surface area. These modifications mitigate transverse interfacial shear by creating strong mechanical interlocking at the interface. This maintains the electronic pathway even during high-rate charging regimes.