Meaning
Spatial inconsistencies in the relative positioning of anode and cathode layers during the winding of cylindrical or prismatic cells represent a critical manufacturing defect. Jellyroll overhang misalignment occurs when the anode margin fails to sufficiently cover the active cathode margin at the ends of the roll. This structural error creates regions where the active cathode lacks an opposing anode surface to receive the lithium ions during charge.
It leads to localized metallic lithium deposition on the edges during the first few cycles.
Defect Genesis
Winding tension fluctuations and alignment sensor errors during the high-speed winding process are the main causes of this positioning failure. If the current collector foil drifts even slightly from its designated path, the active area margins will shift. This drift can be transient or affect the entire roll.
Modern production lines use closed-loop vision systems to minimize these alignment errors.
Electrochemical Danger
Unbalanced capacity ratios at the edges of the active area cause extreme local overpotentials during operation. Lithium ions leaving the cathode have no insertion sites on the corresponding anode area, forcing them to plate as metallic lithium. Over time, these plated deposits grow into dangerous dendrites that can penetrate the separator.
This penetration creates a direct path for internal short circuits and subsequent thermal failure.
Detection Method
High-resolution X-ray or computed tomography scans are used inline to verify overhang dimensions. Any cell with insufficient margins is automatically rejected.