Meaning
External compressive force applied to pouch and prismatic cells controls thickness expansion and optimizes electrochemical performance. Maintaining mechanical clamp pressure keeps the internal layers of the cell in intimate contact to prevent delamination during cycling. This force must be kept within a specific range to avoid crushing the separator or choking the flow of electrolyte.
Industrial battery modules are built with rigid endplates to supply this force.
Force Distribution
Placing soft pads or springs between the cells and endplates prevents localized load peaks from damaging the structure. Uniform mechanical clamp pressure ensures that the active material expands evenly across its entire surface. Uneven forces lead to localized lithium plating and premature degradation.
Thermal Contact
Compression improves heat transfer from the cell body to the cooling plates mounted at the bottom of the module. When mechanical clamp pressure is correct, the thermal resistance of the boundary decreases. This leads to lower internal temperatures during high-rate charging.
Assembly Limit
Designers choose tension bolts that can withstand the swelling forces of the battery pack over its lifetime. Exceeding the specified mechanical clamp pressure can damage the outer cell pouch or cause short circuits. Proper calibration of tightening torque is essential during pack build.