Meaning
Application of a deliberate external short circuit to a fully charged battery at elevated temperatures evaluates the effectiveness of internal safety mechanisms. Performance in test t.5 indicates whether a unit can withstand a major electrical fault without venting or catching fire. The procedure simulates a condition where the terminals are accidentally connected by a conductive object.
Short Circuit
Connection of the positive and negative terminals through a low resistance path creates a sudden surge of current. During test t.5, the resistance of the external loop must stay below 0.1 ohms to ensure a severe test condition. This rapid discharge generates significant internal heat within the cell.
Temperature Condition
Heating the battery to fifty seven degrees Celsius before the short occurs adds thermal stress to the electrical load. Maintaining this environment in test t.5 tests the stability of the separator and the electrolyte. The unit must remain at this temperature for at least six hours after the fault.
Precise control of the oven ensures that the internal chemistry reaches thermal equilibrium before the circuit closes. Digital sensors record the surface temperature of the casing throughout the entire observation window.
Pass Criterion
Success depends on the battery remaining intact without any visible signs of fire or disassembly. Observations for test t.5 focus on the external casing and any temperature spikes that might indicate an internal reaction. No mass loss or leakage is permitted during the observation period.