Meaning
Evaluation of the integrity of a sealed container prevents the ingress of atmospheric moisture and the egress of volatile electrolyte components. Cell hermeticity testing involves assessing the leak rate of a battery to verify that the internal chemistry remains isolated from the external environment. This procedure is performed during the final stages of manufacturing to confirm that the seals and welds are free from microscopic defects.
Helium Tracer
Mass spectrometry measures the passage of helium atoms through the shell of the cell. Helium acts as a surrogate for air or electrolyte because its small atomic size allows it to penetrate even the smallest leak paths. The cell is placed in a vacuum chamber, and a detector counts the number of helium ions present in the exhaust stream.
Moisture Barrier
Protection against water vapor is the primary reason for maintaining a high level of seal integrity. Even trace amounts of moisture react with lithium salts to form hydrofluoric acid, which corrodes the internal components and degrades the capacity. A secure seal prevents this reaction from occurring over the multi-year life of the device.
Leakage Limit
Standards define the maximum allowable gas flow that a product can exhibit before it is rejected by the quality control system. A typical threshold for lithium-ion cells sits between one millionth and one billionth of a standard cubic centimeter per second of helium. Higher leak rates indicate a risk of electrolyte loss, which could eventually lead to cell dry-out or the release of flammable gases into the battery module.
Engineering teams select these limits based on the volume of the cell and the required shelf life, ensuring that the quantity of electrolyte lost over ten years remains below a specific mass percentage.