Meaning
Regulatory tests defined by the United Nations Manual of Tests and Criteria verify that lithium-ion cells can survive high-acceleration physical impacts without leakage or fire. The test mechanical shock t.5 subjects cells or battery packs to half-sine shock pulses that simulate transport accidents. It is part of the standard UN38.3 transport certification sequence.
Passing is mandatory before cells can be shipped globally by air or sea, making it a critical baseline for compliance and distribution logistics.
Test Profile
Acceleration levels reach up to one hundred and fifty times the force of gravity for small cells or fifty times for larger battery packs. The shock is applied in three positive and three negative directions across three mutually perpendicular mounting axes. This exposes all internal and external structural components to sudden mechanical stress.
Safety Verification
Cells must show no mass loss, no leakage, no venting, and no temperature rise above a specified threshold to pass the test. The open-circuit voltage after testing must remain within a fraction of a percent of its pre-test value. This ensures the internal electrode stack remains intact and free from short circuits.
Cell Durability
Procurement contracts for cells destined for automotive or industrial use require proof of compliance with mechanical shock t.5 as a baseline safety requirement. This certification must be renewed if any material changes are made to the cell chemistry or internal structure. Verification of certification helps filter cell suppliers during procurement.