Meaning
Localized surface corrosion initiates microscopic cavities on metallic current collectors, busbars, and plating layers under electrochemical and mechanical stress. Micro-pitting breakdown occurs when protective oxide films or electroplated barrier layers suffer localized chemical dissolution or fretting wear. This degradation mode governs the mechanical integrity and contact resistance of electrical interfaces in aggressive environments.
The phenomenon applies to metal surfaces subjected to localized electric fields and electrolyte exposure, ending where uniform bulk corrosion takes over.
Pitting Mechanism
Chloride ions or acidic electrolyte breakdown products concentrate inside micro-cracks on the metal surface. Local anodization accelerates metal ion dissolution within tiny pits while surrounding passive areas remain unattacked. Micro-pitting breakdown destabilizes surface uniformity and creates high electric field concentrations that accelerate localized pitting.
Structural Damage
Cavity formation reduces effective cross-sectional area and creates stress concentration sites within thin foil current collectors. Mechanical vibration propagates fatigue cracks from these microscopic pits, leading to premature foil rupture. Pitted busbar interfaces suffer higher contact resistance and localized overheating.
Mitigation Strategy
Applying dense electroplated nickel or specialized polymer coatings prevents corrosive chemical agents from contacting susceptible base metals. Surface polishing reduces initial micro-asperity height and minimizes stress concentration sites. Maintaining clean manufacturing conditions limits halogen contamination on active cell interconnects.