Meaning
Destructive physical analysis involves the systematic disassembly of a battery in a controlled environment to investigate the causes of degradation or failure. A post mortem cell teardown provides direct evidence of internal changes that non-invasive testing cannot reveal. Technicians perform this work inside an inert gas glove box to prevent moisture and oxygen from reacting with the sensitive cell chemistry.
Component Analysis
Microscopic inspection of the harvested materials shows the extent of chemical aging. During a post mortem cell teardown, the electrodes are washed and examined for lithium plating, particle cracking, pore clogging or thickness changes. Chemical analysis of the electrolyte identifies decomposition products that indicate high temperature exposure.
High magnification imaging of the separator can reveal the presence of tiny metallic bridges that would eventually lead to an internal short circuit.
Failure Mode
Identifying the root cause of a thermal event or a sudden loss of capacity is the primary goal of this investigation. The post mortem cell teardown looks for signs of internal short circuits such as dendrite growth or separator melting. Finding a metallic contaminant inside the jelly roll points toward a manufacturing defect rather than operational abuse.
Specialized Equipment
Laboratory safety protocols prevent hazardous releases during the opening of the casing. Because a post mortem cell teardown often involves damaged or unstable cells, fire suppression systems and blast shields are standard requirements. Proper disposal of the hazardous waste generated during the process follows strict environmental regulations.