Meaning
A standardized safety evaluation subjects battery cells or modules to rapid, extreme temperature transitions to verify their structural and electrochemical integrity. As part of international transport regulations, thermal shock test t.2 exposes cells to high and low temperature limits within a short timeframe, simulating the harsh conditions of air transport. This evaluation ensures that cells will not catch fire or leak when exposed to sudden environmental changes.
Sourcing and safety compliance teams use this test to qualify batteries for global shipment.
Test Execution
The protocol requires cells to be stored at a high temperature of seventy-two degrees Celsius followed by a rapid transition to minus forty degrees Celsius. In thermal shock test t.2, this cycle is repeated ten times, with cells remaining at each temperature extreme for at least six hours. The transition between these temperatures must occur in less than thirty minutes, which puts extreme thermal stress on the internal seals and casing.
This rapid cycling reveals defects in weld joint integrity and material matching. By forcing these rapid expansion and contraction cycles, the test highlights any mismatch in the thermal expansion coefficients of the active materials and the protective packaging.
Verification Criteria
Post-test inspection focuses on mechanical distortion and open circuit voltage retention. To pass thermal shock test t.2, the cell must show no evidence of leakage, venting, disassembly, or rupture. Additionally, the open circuit voltage after the test must not be less than ninety percent of its pre-test value.
This electrical check ensures that the internal connections have not been disrupted by the thermal stress.
Safety Consequence
Passing this rigorous stress test is a legal prerequisite for the commercial transport of lithium-based batteries. If a battery design fails this evaluation, it cannot be shipped by air or sea, which effectively blocks it from entering global supply chains. This makes the evaluation a critical milestone in the product development cycle for cell manufacturers.