Meaning
Electrical resistance testing technique utilizing separate pairs of current-carrying and voltage-sensing electrodes eliminates the influence of lead and contact resistance from the measurement value. Implementing a four-terminal measurement allows for highly accurate resistance calculations in low-impedance systems. The method is standard in battery cell testing and materials characterization.
It establishes a true value for internal resistance.
Circuit Arrangement
An outer pair of terminals supplies a known electrical current to the test subject while an inner pair of terminals measures the resulting voltage drop. In a four-terminal measurement setup, almost no current flows through the voltage sensing leads. This lack of current prevents lead resistance from causing a voltage drop along those lines.
Consequently, the voltmeter measures only the voltage across the device itself.
Accuracy Control
Sensing lines are designed with high input impedance to minimize parasitic currents. When performing a four-terminal measurement, the resistance of the contact points becomes irrelevant because no significant current traverses them. This ensures that variations in contact force do not alter the test outcome.
Decoupling the sensing from the current makes the measurement highly repeatable.
Sourcing Relevancy
Battery cell buyers rely on this method during incoming quality control to verify cell health. Using four-terminal measurement detects internal manufacturing defects early. This prevents the integration of high-resistance cells into packs.