Meaning
A temporal offset in the conversion of analog battery data into digital format affects the accuracy of real-time monitoring and control. Sampling delay occurs due to the processing time of the analog-to-digital converter and the travel time of the signal through the communication bus. This parameter is critical in high-frequency applications where the state of the battery changes faster than the controller can react.
Latency Source
Hardware filters used to remove high-frequency noise introduce a lag into the measurement path. When sampling delay is not compensated for in the software, the battery management system works with data that represents a past state of the cell. Software overhead in the microcontroller further adds to this delay, especially when the processor is managing multiple tasks such as balancing, thermal control, and communication.
Modern systems use direct memory access and hardware triggers to bypass the central processor and minimize the time between the sensor trigger and the storage of the data point.
Phase Distortion
Correlation of voltage and current signals is compromised when the two measurements experience different amounts of lag. Because sampling delay shifts the measured values in time, the calculated phase angle in impedance spectroscopy will be incorrect unless a precise calibration is performed.
Control Stability
Feedback loops for fast-charging protocols can become unstable if the delay in the voltage reading is too large.