Meaning
Chain reaction mechanism involves the transfer of hazardous heat from a single failing cell to the surrounding units within a shared enclosure. When module thermal propagation occurs, the energy released by one cell triggers a second cell, eventually consuming the entire energy storage unit. Safety standards like UL 9540A test the ability of a design to stop this process before it reaches the module boundary.
Barrier Performance
Internal insulation blocks the conductive and radiative heat paths between adjacent cells. Materials used to prevent module thermal propagation include mica sheets, aerogels, ceramic blankets or specialty foams that can withstand temperatures above one thousand degrees Celsius. These dividers buy time for the cooling system to remove excess energy from the area.
Safety Testing
Certification requires a deliberate initiation of a failure to observe how the system responds. During these tests, module thermal propagation is considered a failure if flames or high temperatures spread beyond the tested module to neighboring equipment.
Energy Release
Total heat output scales with the number of cells involved in the event. If the design fails to contain module thermal propagation, the resulting fire is much harder to extinguish than a single cell event. The total mass of flammable gas produced also increases, which creates a higher risk of a secondary explosion.