Verifying UN 38.3 Test Summary Requirements for Lithium Battery Air Transport

Verifying UN 38.3 test summaries requires matching physical cell markings, mass, and laboratory ISO 17025 scope against mandatory section 38.3.5 fields.

29.08.26 19 min

Cargo

A ground handling clerk at Frankfurt Airport rejected a pallet of 2,400 lithium-ion 21700 cells because the accompanying UN 38.3 test summary listed a cell mass of 68.2 grams, while the scale at the airside acceptance desk read 69.5 grams per unit. That mismatch triggered an immediate hold, grounding the shipment and exposing the buyer to airline demurrage fees. Document verification begins right at the acceptance counter.

Air transport rules for energy storage products are tight to prevent thermal runaway in flight, and Section 38.3 of the United Nations Manual of Tests and Criteria sets the baseline safety testing every lithium cell and battery design must pass before loading onto commercial flights.

Because cell mass dictates transport classification, paperwork attributes must match the physical goods delivered to the freight forwarder. Under both the International Civil Aviation Organization Technical Instructions and the International Air Transport Association Dangerous Goods Regulations, lithium batteries are regulated as high energy density risks. Approval hinges on proving a design type survived intense mechanical, thermal, and electrical abuse testing without disassembly, rupture, leakage, or thermal runaway.

A prototype battery pouch cell compression jig with leather straps rests on a grey granite workbench in a manufacturing lab.

Mandatory Ten Elements of Section 38.3.5

Paragraph 38.3.5 of the UN Manual of Tests and Criteria specifies the exact fields mandatory for a compliant test summary. Where manufacturers once provided lengthy, redacted lab reports or simple letters of conformity, current rules require a standardized, standalone document containing ten specific operational fields. These fields form a traceable line connecting the cell manufacturer, the testing lab, and the physical freight entering the logistics network.

UN 38.3.5 Mandatory Field Compliance Matrix and Common Verification Failure Modes
UN 38.3.5 Field Requirement Mandatory Technical Content Common Audit Failure Mode Rejection Consequence at Freight Desk
Manufacturer Identification Name, address, phone number, email, and website of cell/battery manufacturer Listing a trading company or local broker instead of the physical factory owner Immediate rejection; carrier cannot verify manufacturing quality system origin
Test Laboratory Credentials Name, address, phone, email, website of testing facility performing T.1-T.8 Omission of laboratory contact details or listing unaccredited in-house desks Cargo hold pending direct verification of laboratory ISO 17025 accreditation
Report Identifier and Date Unique test report number and date of issuance matching raw laboratory logs Date mismatch between summary sheet and underlying test report reference Documentation failure; forwarder treats summary as unverified secondary record
Product Description Cell or battery type, chemistry, mass, watt-hour rating, or lithium content Stating nominal capacity while omitting physical mass or exact chemistry formulation Customs detention due to inability to verify packing instruction energy cutoffs
Physical and Parameter Lists Detailed physical description, shape, model numbers, and internal construction Generic series listing (e.g. 18650 Series) without exact suffix specification Refusal to load; carrier auditor cannot match outer carton label to summary
Executed Test List Explicit confirmation of completed sub-tests T.1 through T.8 with pass results Omitting T.6 for component cells or T.7 for rechargeable battery pack assemblies Regulatory non-conformity; shipment classified as uncertified dangerous goods
Signature Block Name and title of authorized signatory indicating document authenticity Unsigned documents or generic corporate stamps lacking named individual title Document invalidation; forwarder refuses Shipper’s Declaration endorsement

Each field serves a specific purpose during transport audits, and missing or generic entries render the entire summary invalid. Freight forwarders match the model designation on the document against the print on the cell sleeve or battery casing. A mismatch between the declared part number and the inspected unit suggests an unverified design revision or an unauthorized cell substitution by an upstream pack assembler.

Freight forwarders accept paperwork that matches physical markings on the crate and reject files carrying ambiguous model designations.

A paperwork discrepancy grounds the cargo. If the weight, dimensions, or electrical specifications on the summary deviate from measurements taken at the receiving depot, ground handlers flag the shipment as uncertified dangerous goods.

Metallic dendrites bridge electrical contacts inside a test fixture equipped with a digital measuring instrument under low temperatures.

Air Carriage Classification and Packing Instructions

Regulations divide lithium ion transport into separate packing instructions based on how the items are packaged. Standalone cells and batteries fall under Packing Instruction 965. Cells packed alongside equipment move under Packing Instruction 966, while those installed in equipment fall under Packing Instruction 967.

Standalone cells under PI 965 are prohibited on passenger aircraft and travel exclusively on cargo freighters. Additionally, their state of charge cannot exceed 30 percent of rated nominal capacity at the time of transport.

Verifying state of charge requires open-circuit voltage checks during incoming inspection or dock receiving. For a standard nickel manganese cobalt cell rated at 3.6 V nominal and 4.2 V fully charged, a 30 percent state of charge translates to a resting open-circuit voltage between 3.50 V and 3.62 V, depending on the specific chemistry. Forwarders reject lots above that 30 percent limit because higher charge levels intensify the energy released if a thermal runaway occurs.

Missing thermal test parameters recently held three air pallets at Leipzig, generating 14,200 EUR in demurrage and re-inspection charges. To avoid such holds, standard policy requires every inbound cell shipment to carry a validated test summary cross-referenced against original laboratory test logs before booking instructions are issued to freight forwarders.

Standard

Testing protocols under UN 38.3 expose cells and battery packs to environmental, mechanical, and electrical stresses that simulate flight conditions. The procedure comprises eight sub-tests, designated T.1 through T.8, targeting specific transport hazards and failure modes. Depending on the cell or pack configuration, a design type undergoes these tests sequentially or in parallel batches.

Cell mass dictates the severity of testing. Sub-tests T.1 through T.5 run sequentially on a single sample set of cells or batteries. Sub-test T.6 applies to component cells, T.7 covers rechargeable battery assemblies, and T.8 subjects primary and secondary component cells to forced discharge.

Heavy steel wire mesh container holding stacked energy storage modules rests on a concrete floor beneath an industrial assembly fixture within a production facility.

Stress Profiles across Sub-Tests T1 through T5

Environmental simulation starts with T.1 Altitude Simulation. Test chambers reduce internal pressure to 11.6 kPa or lower, simulating an unpressurized cargo hold at an altitude of 15,000 meters. Samples remain at this pressure for at least six hours at 20 degrees Celsius.

Passing requires that units show no mass loss beyond allowed thresholds, maintain at least 90 percent of their pre-test open-circuit voltage, and exhibit no leakage, venting, disassembly, rupture, or fire.

Sub-test T.2 subjects those same samples to extreme thermal cycling, moving units between minus 40 degrees Celsius and plus 72 degrees Celsius. Temperature transitions must take place within 30 minutes, with dwells at each temperature extreme lasting at least four hours. The sequence runs for ten continuous cycles, followed by a 24-hour ambient storage period before final inspection.

These rapid swings place heavy stress on hermetic seals, welds, and internal plastic separators.

UN 38.3 Test Sequence Parameter Thresholds and Physical Pass Criteria
Sub-Test Designation Stress Parameter Specification Required Sample Quantity Physical Pass Criteria Limits
T.1 Altitude Simulation Pressure ≤ 11.6 kPa; Duration: 6 hours minimum; Temperature: 20°C 10 cells / 4 batteries (fully charged/discharged split) Mass loss < Table 38.3.1 limit; OCV retention > 90%; No fire/venting
T.2 Thermal Test T_min: -40°C, T_max: +72°C; 10 cycles; 4-hour dwell; transition < 30 min Same samples from T.1 test sequence Mass loss < Table 38.3.1 limit; OCV retention > 90%; No seal leakage
T.3 Vibration 7 Hz to 200 Hz sweep; Peak accel: 1 gn (large) or 8 gn (small); 3 hours/axis Same samples from T.2 test sequence Mass loss < Table 38.3.1 limit; OCV retention > 90%; No internal short
T.4 Shock 150 gn / 6 ms (small) or 50 gn / 11 ms (large); 3 shocks per direction (18 total) Same samples from T.3 test sequence Mass loss < Table 38.3.1 limit; OCV retention > 90%; No cell distortion
T.5 External Short Circuit T_ambient: 55°C; External resistance < 0.1 Ω; Hold 1 hour past T < 55°C Same samples from T.4 test sequence Internal cell temp < 170°C; No fire/disassembly within 6 hours post-test

Sub-test T.3 introduces mechanical vibration. Test rigs execute a sinusoidal sweep from 7 Hz to 200 Hz and back over 15 minutes, repeating for three hours across each of three perpendicular axes. For cells and small batteries, peak acceleration hits 8 gn at higher frequencies, maintaining a constant displacement of 0.8 mm at lower frequencies.

Sub-test T.4 follows immediately with mechanical shock, applying half-sine pulses to the samples. Small cells experience 150 gn peak acceleration over a 6-millisecond duration, taking three shocks in both positive and negative orientations across three axes, totaling 18 shocks.

Sub-test T.5 measures external short-circuit response at elevated temperatures. Test chambers heat the samples to 55 degrees Celsius, with external wiring keeping total loop resistance under 0.1 ohm. If internal safety mechanisms fail, a short circuit can trigger thermal runaway.

The short circuit is held for at least one hour after the outer case temperature cools back down to 55 degrees Celsius. To pass, outer case temperatures must remain under 170 degrees Celsius, with zero disassembly, rupture, or fire during the six hours following the test.

Clause 38.3.5 of the UN Manual of Tests and Criteria obligates cell manufacturers and subsequent distributors to make the test summary available throughout the supply chain without prior request.

The T.5 peak short-circuit current depends on a 0.08-ohm loop resistance at 55 degrees Celsius; a 5 milliohm shift in fixture impedance can swing peak current from 420 A to 510 A. Lower impedance speeds up the surge rate, triggering swift internal Joule heating before positive temperature coefficient devices trip or current interrupt mechanisms disconnect. Any test report recording short-circuit resistance above 0.1 ohm breaches T.5 limits, rendering the summary legally invalid for freight clearance.

A digital rendering shows a metallic industrial power storage module secured within a steel frame between railway tracks on a gravel bed.

Destructive Evaluation Mechanics in T6 through T8

Sub-tests T.6 through T.8 perform destructive evaluation on fresh sample sets. Sub-test T.6 tests component cells using impact or crush methods based on physical format. Cylindrical cells exceeding 20 mm in diameter undergo impact testing: a 9.1-kilogram mass drops from 61 centimeters onto a 15.8-millimeter bar placed across the center of the cell.

Prismatic and pouch cells, along with cylindrical cells under 20 mm in diameter, are subjected to crush testing instead. A hydraulic press exerts a 13-kilonewton force along the longitudinal axis at 1.5 centimeters per second until peak pressure is reached, cell voltage drops by 100 millivolts, or the unit deforms to 50 percent of its original thickness.

Sub-test T.7 evaluates overcharge response in rechargeable battery packs. The setup supplies a charging current double the manufacturer’s maximum continuous rating, capping voltage at twice the maximum charge voltage or 22 V depending on system architecture. This overcharge is applied continuously for 24 hours.

The pack cannot disassemble or catch fire during the test or across a seven-day post-test observation window. Sub-test T.8 forces deep discharge on component cells by connecting a cell in series with a DC power source to force reverse current ~ matching the maximum continuous discharge rating ~ for a duration equal to nominal capacity divided by rated current.

Under Section 38.3.2.1, any change in cathode active material loading exceeding 20 percent requires complete re-qualification across sub-tests T.1 through T.8.

Dispute

Disputes often arise when pack builders attempt to use individual component cell test summaries to cover fully assembled multi-cell battery packs. A cell-level summary confirms only that the bare cell passed sub-tests T.1 through T.6 and T.8. It offers no evidence regarding mechanical housing, busbar welds, current distribution, thermal management, or Battery Management System protection circuitry in a finished assembly.

Freight acceptance rules explicitly require separate UN 38.3 testing for battery packs containing multiple cells.

Swapping internal cells voids existing pack summaries. If an assembly plant replaces an approved 2,500 mAh 18650 cell with a 2,600 mAh alternative from another supplier or chemistry line, the finished pack loses its UN 38.3 qualification. Paragraph 38.3.2.1 outlines clear re-testing thresholds: any design change altering pack mass by more than 0.1 grams or 20 percent, shifting nominal watt-hour energy by over 20 percent, or modifying internal series-parallel routing demands new physical testing of the updated pack.

A cylindrical energy storage cell is secured by a woven polymer restraint strap inside a metallic storage compartment drawer.

Re-Testing Thresholds for Modified Battery Assemblies

Whether a modification demands full re-testing under T.1 through T.7 or partial verification depends on structural severity. Changing external enclosure materials, altering copper busbar dimensions, or updating Battery Management System firmware can change how a pack behaves during mechanical shock (T.4) or external short circuit (T.5). During factory documentation audits, model number mismatches account for nearly half of all administrative holds.

The technical dossier must establish a direct line of sight from raw cell test reports through pack engineering drawings to final summary certificates. Short-circuit testing on large battery assemblies releases substantial energy if safety circuits hesitate. Where a design relies on solid-state MOSFETs for isolation, short-circuit current during sub-test T.5 must not bypass protection gates or fuse contacts shut.

Common administrative non-conformities found during technical inspections of transport documentation include:

  • Unmatched cell part numbers listed on battery pack test summaries where component cell designations conflict with the underlying cell-level test report.
  • Missing test report reference numbers preventing cross-verification between summary sheets and original laboratory test execution logs.
  • Discrepant mass allocations where physical pack weight measured at freight docks exceeds declared mass limits by more than five percent.
  • Unaccredited test lab signatures lacking verified ISO 17025 scope certificates for lithium battery safety methodologies under UN 38.3.
  • Omitted overcharge parameters on rechargeable battery pack summaries failing to record maximum charge voltage and continuous current ratings.
An industrial concrete and steel structure frames an open elevator shaft with exposed cables, pulleys, and robust guide rails ascending into the light.

Is Component Cell Qualification Sufficient for Assembled Packs?

Standalone cell qualification never replaces assembled pack testing. Component cells require individual UN 38.3 summaries to ship independently under PI 965, but installing those cells inside a series-parallel enclosure creates a distinct dangerous goods entity. That complete battery assembly must pass sub-tests T.1 through T.5 and sub-test T.7 before air carriers will clear the shipment.

Testing costs vary depending on format. Pack-level short-circuit testing under T.5 checks whether inter-cell fuses, current-limiting resistors, and Battery Management System cutoffs hold up under heavy current draw. If internal connections melt or arc during T.5, thermal propagation between cells can destroy the entire pack on the test bench.

Individual component cell test summaries do not grant an assembled 14S4P battery pack inherited compliance without undergoing physical testing under T.7.

Inspection

Verifying incoming test summary sheets requires cross-checking document fields against accredited lab databases and physical shipment samples. Buyers cannot rely solely on certificates handed over by sales intermediaries. Digital editing tools make it simple to generate fabricated summary forms stamped with bogus lab logos, so incoming quality checks must build an unbroken chain of custody connecting physical cell markings, test summary declarations, and independent lab accreditations.

Testing facilities must maintain explicit ISO 17025 accreditation for UN 38.3 protocols. Credentials ought to be backed by recognized bodies affiliated with the International Laboratory Accreditation Cooperation Mutual Recognition Arrangement, including CNAS, A2LA, NVLAP, or UKAS. If a facility lacks valid ISO 17025 accreditation covering UN Section 38.3, its test summaries carry no legal standing for international air freight clearance.

A mechanical test rig centers a component fixture before a wall mounted array of electronic battery management modules within a controlled laboratory environment.

Accreditation Traceability and Laboratory Credentials

Verification specialists check testing scope schedules directly on accreditation body websites. These documents lay out the exact test standards, parameters, and boundaries a lab is certified to handle. A lab accredited for general safety testing under IEC 62133 is not automatically certified for UN 38.3 transport testing unless UN Section 38.3 appears on its official scope schedule.

Quality auditors trace every test report number back to the issuing lab’s scope schedule.

Even with a lab signature present, verification must confirm that the individual is registered as an authorized representative of the accredited facility. Unregistered signatures, generic corporate stamps, or illegible scrawls represent non-conformities that cause forwarders to reject documentation during carrier acceptance.

Laboratories operating under ISO 17025 accreditation retain physical raw test channel log data for five years following test summary issuance.

ISO 17025 accreditation checks rely on public database lookups, where a 90-day lag in scope renewal updates can leave an active test report temporarily unverifiable. During those administrative gaps, strict freight forwarders will refuse cargo clearance until the issuing lab provides direct written confirmation alongside an updated accreditation certificate.

Electronic enclosures and a cylindrical battery cell rest on gravel against steel railway tracks alongside a blank memo card.

Stepwise Audit Protocol for Incoming Technical Summaries

Execution of incoming verification checks follows a standardized physical and administrative process to catch discrepancies prior to packaging assembly or freight booking:

  1. Cross-check the factory legal name on the test summary against the ISO 9001 quality certificate.
  2. Verify the test report reference number directly in the laboratory online public registry.
  3. Validate the laboratory accreditation scope document under ISO 17025 for UN 38.3 methodologies.
  4. Measure physical cell dimensions and weight against summary parameters across ten sample units.
  5. Inspect the test summary signature block for named authorized signers and operational titles.

Running through these five steps before tendering cargo to air carriers prevents customs holds, expensive tarmac delays, re-testing holds, and regulatory fines under dangerous goods enforcement rules.

A test summary signed by a sales manager rather than a qualified laboratory technical director signals an unverified third-party document.

Contract

Commercial agreements between cell buyers and battery vendors must define clear obligations regarding dangerous goods certification, document delivery schedules, and regulatory liability. When a non-compliant lithium battery shipment leads to an in-flight thermal event, an emergency diversion, or a rejection at a transit hub, financial losses extend well beyond damaged cargo. Civil aviation authorities impose heavy fines on importers of record who tender non-compliant dangerous goods.

Title 49 of the United States Code of Federal Regulations (49 CFR 173.185) and international dangerous goods rules hold the shipper of record legally responsible for documentation accuracy.

Buyers typically structure procurement contracts to place transport documentation liability directly on the vendor. Supply agreements should require suppliers to deliver validated, lab-backed UN 38.3 test summaries before cells ship. Contracts should also specify that any design alteration triggering re-testing under paragraph 38.3.2.1 obligates the vendor to re-qualify the design at their own expense prior to delivering modified units.

A heavy lithium battery module and metal enclosure are secured with straps on a cargo pallet inside an aircraft freight hold.

Regulatory Exposure for Importers of Record

Importers of record bear strict civil liability for dangerous goods compliance when tendering cargo to air carriers. Standard freight insurance policies exclude coverage for loss, damage, or third-party liability resulting from illegal or non-compliant dangerous goods. If an uncertified cell design causes damage aboard an aircraft, vessel, or warehouse, underwriters routinely deny claims under illegal carriage exclusions.

Unapproved design changes void active certificates. When a vendor modifies separator thickness, electrolyte formula, or cathode suppliers without re-qualifying under UN 38.3, the original summary becomes legally invalid. Tendering those cells leaves shippers operating without valid dangerous goods certification, exposing company officers to civil penalties and potential prosecution under aviation safety laws.

Contractual Risk Allocation Matrix for Air Carriage Compliance Obligations
Supply Chain Role Primary Regulatory Obligation Financial Exposure for Breach Mandatory Contractual Protective Clause
Cell Manufacturer Execute T.1-T.8 testing; issue compliant UN 38.3.5 summary Product liability; product recall expenses; lab re-test costs Design Freeze Covenant; UN 38.3 Warranty & Indemnity Clause
Pack Integrator Execute pack-level T.1-T.7 testing; maintain cell traceability Assembly re-testing costs; customer breach of contract claims Cell Lineage Warranty; Mandatory Re-test Notification Clause
Importer of Record Verify summary accuracy; issue Shipper’s Declaration Civil aviation fines; carrier demurrage; insurance claim denial Pre-Shipment Audit Right; Supply Holdback Indemnification
Freight Forwarder Audit paperwork; verify outer packaging labels and PI rules Carrier penalties; ground license suspension; warehouse holds Dangerous Goods Compliance Verification Right

Air cargo rejection rates for incomplete UN 38.3 paperwork are estimated between 4 percent and 12 percent across major Asian hubs, reflecting variable carrier pre-check standards. Buyers hedge this risk by requiring documentation sign-off prior to booking cargo space. International air freight rates surge during peak consumer electronics export seasons, prompting forwarders to review paperwork closely to prevent tarmac bottlenecks.

Acceptance desks will not commit hold space to shipments with doubtful paperwork when cargo capacity commands peak seasonal rates.

A metallic chemical container rests on a wooden industrial pallet secured by blue cargo straps upon a steel laboratory table.

Structuring Supply Agreements for Transport Compliance

Commercial purchasing agreements enforce compliance by binding vendor payments directly to technical documentation acceptance milestones. Supply contracts should incorporate targeted clauses:

  • Mandatory document delivery schedules linking final invoice payment release to successful verification of UN 38.3 test summaries and ISO 17025 lab scope files.
  • Indemnification for carriage delay costs requiring vendors to reimburse demurrage, administrative fines, and air freight re-booking charges caused by improper paperwork.
  • Third-party laboratory validation rights granting buyers authority to submit random production samples to independent test labs for re-qualification auditing.
  • Design freeze notification covenants obligating vendors to provide 90 days written notice before making any manufacturing change altering cell mass or energy metrics.

Because insurance policies exclude uncertified cargo, structuring contracts around these operational parameters protects buyers from absorbing financial losses caused by unexpected vendor substitutions or missing paperwork.

An open question in the industry is how national aviation authorities will assign liability when an automated packaging platform generates a fake test summary without the factory owner’s knowledge.

Gate

Acceptance desks at air freight terminals serve as the final checkpoint for dangerous goods compliance. Ground handling staff inspect incoming pallets against IATA Dangerous Goods Regulations checklists before clearing cargo for loading into unit load devices. Agents verify that model numbers, watt-hour ratings, cell masses, and shipper details on outer packaging match the UN 38.3 test summary down to the character.

Ground handling agents audit incoming dangerous goods packages against test summary data. Any discrepancy caught at the acceptance desk stops the shipment immediately. Ground crews transfer non-compliant pallets to secure hold areas and issue formal query notices to the freight forwarder and shipper of record.

An automated test fixture equipped with circuit boards assesses wall mounted hardware inside an industrial battery energy storage facility.

Carrier Acceptance Workflows at Major Air Freight Hubs

Major air hubs enforce carrier-specific policies alongside standard IATA Dangerous Goods Regulations. Commercial airlines maintain dedicated dangerous goods desks that re-audit all UN 38.3 test summaries prior to confirming booking space. These desks cross-reference report numbers against internal watchlists of unaccredited labs and flagged manufacturers.

A shipment cleared by a freight forwarder can still be turned back by the air carrier during final airside review.

When loading is halted, pallets left in airside hold areas accrue daily storage fees while paperwork errors are resolved. If corrections require issuing a new summary from an accredited lab, the delay often exceeds acceptable transit windows, leaving shippers to pay return freight or abandon cargo for hazardous waste disposal.

A 3D render presents a horizontal amber liquid filled cylindrical test cell secured within a metal assembly base.

Resolving Airside Packaging and Paperwork Discrepancies

Ground handling delays resolve only when shippers produce verified documentation directly from an accredited ISO 17025 lab. Fixing errors on a UN 38.3.5 summary requires the original facility to issue an official amended document bearing a revised report ID that references the underlying test log numbers.

Airline cargo acceptance clerks verify the test summary model designation against the outer package hazard label before authorizing pallet loading.

Operational readiness relies on establishing solid verification procedures long before cells arrive at air freight gates. Shippers who maintain disciplined documentation chains, verify lab accreditations, and enforce strict contract terms pass security checks without operational delays or financial loss.

Nomenclature

Mass Loss Limit

Meaning ~ A maximum allowable reduction in mass during a specified environmental test sequence provides a quantified threshold for material stability.

Short Circuit

Meaning ~ This abnormal electrical condition occurs when an unintended low-resistance path is established between the positive and negative terminals of an electrochemical cell or circuit.

ISO 17025 Accreditation

Meaning ~ ISO 17025 accreditation is an international standard that specifies the general requirements for the competence, impartiality, and consistent operation of testing and calibration laboratories.

Freight Forwarder Audit

Meaning ~ A formal verification process establishes whether third party logistics entities hold the necessary financial stability, operational licenses, and safety certifications to handle client goods according to specific contractual obligations.

IATA Dangerous Goods

Meaning ~ Aviation transport rules govern the safe handling, packaging, labeling and documentation of lithium batteries offered for commercial air freight worldwide.

T.1 Altitude Simulation

Meaning ~ Mandatory safety procedure for shipping batteries replicates the low pressure conditions of an aircraft cargo hold to ensure the structural integrity of the cell casing.

Cylindrical Cells

Meaning ~ This format of lithium ion energy storage uses a round steel or aluminum enclosure to house a tightly wound electrode assembly known as a jelly roll.

Shipper Declaration

Meaning ~ A shipper declaration is a formal written statement provided by the consignor of hazardous materials that certifies the cargo meets all regulatory standards for safe transport.

UN 38.3

Meaning ~ A mandatory United Nations testing standard outlines safety requirements for the transport of lithium metal and lithium-ion batteries.

PI 967

Meaning ~ Packing instructions published by the International Air Transport Association govern the commercial shipping of lithium ion batteries contained in equipment by air.

External Short Circuit

Meaning ~ Connecting the positive and negative terminals through a low resistance external path creates a massive surge in electrical current.

T.2 Thermal Test

Meaning ~ Environmental stress evaluation subjects batteries to rapid and extreme temperature fluctuations to assess the stability of internal components and seal integrity.